logo

Camphor Safety Data Sheet (SDS)

SDS #: 209
Revision Date: September 22, 2014
SECTION 1 — CHEMICAL PRODUCT AND COMPANY IDENTIFICATION

Camphor

Flinn Scientific, Inc. P.O. Box 219, Batavia, IL 60510 (800) 452-1261
Chemtrec Emergency Phone Number: (800) 424-9581
Signal Word
WARNING
SECTION 2 — HAZARDS IDENTIFICATION
Hazard class: Flammable solids (Category 2). Flammable solid (H228). Keep away from heat, sparks, open flames, and hot surfaces. No smoking (P210).

Hazard class: Acute toxicity, oral (Category 4). Harmful if swallowed (H302). Do not eat, drink or smoke when using this product (P270).

Hazard class: Skin and serious eye damage, corrosion or irritation (Category 2, 2A). Causes skin and serious eye irritation (H315+H319).

Hazard class: Specific target organ toxicity, single exposure; Respiratory tract irritation (Category 3). May cause respiratory irritation (H335). Avoid breathing dust or fumes (P261).
Pictograms
SECTION 3 — COMPOSITION, INFORMATION ON INGREDIENTS
Component Name CAS Number Formula Formula Weight Concentration
d-Camphor

76-22-2 C10H16O 152.25
SECTION 4 — FIRST AID MEASURES
If exposed or concerned: Get medical advice or attention (P308+P313).
If inhaled: Remove victim to fresh air and keep at rest in a position comfortable for breathing (P304+P340).
If in eyes: Rinse cautiously with water for several minutes. Remove contact lenses if present and easy to do so. Continue rinsing (P305+P351+P338). If eye irritation persists eyes: Get medical advice or attention (P337+P313).
If on skin: Rinse cautiously with water for several minutes (P351).
If swallowed: Rinse mouth. Call a POISON CENTER or physician if you feel unwell (P301+P330+P312).
SECTION 5 — FIRE FIGHTING MEASURES
Class IIIA combustible solid.
Flash point: 66 °C; Flammable limits: lower 0.6% and upper 3.5%; Autoignition temperature: 466 °C
Vapor is explosive when exposed to heat, flame, or CrO3.
In case of fire: Use class D fire extinguisher or dry sand for extinction (P370+P378).
NFPA Code
H-2
F-2
R-0
SECTION 6 — ACCIDENTAL RELEASE MEASURES
Remove all ignition sources and water. Sweep up the spill, place in a sealed bag or container, and dispose. Ventilate area and wash spill site after material pickup is complete. See Sections 8 and 13 for further information.
SECTION 7 — HANDLING AND STORAGE
Flinn Suggested Chemical Storage Pattern: Organic #4. Store with ethers, ketones, and halogenated hydrocarbons.
Store in a dedicated flammables cabinet. If a flammables cabinet is not available, store in Flinn Saf-Stor™ can.
Keep container tightly closed (P233). Ground or bond container and receiving equipment (P240). Use only in a hood or well-ventilated area (P271).
SECTION 8 — EXPOSURE CONTROLS, PERSONAL PROTECTION
Wear protective gloves, protective clothing, and eye protection (P280). Wash hands thoroughly after handling (P264). Use only in a hood or well-ventilated area (P271).
Exposure guidelines: PEL/TLV 2 mg/m3 (OSHA, ACGIH) Ceiling 3 mg/m3 (ACGIH)
SECTION 9 — PHYSICAL AND CHEMICAL PROPERTIES
Colorless or white crystals. Penetrating aromatic odor.
Soluble: Many organic solvents. Slightly in water. Sublimes slowly at room temperature.
Boiling point: 204 °C
Melting point: 176 °C
Specific gravity: 0.99

SECTION 10 — STABILITY AND REACTIVITY
Avoid contact with strong oxidizers.
Shelf life: Indefinite, if stored properly.
SECTION 11 — TOXICOLOGICAL INFORMATION
Acute effects: Irritant, nausea, vomiting, diarrhea, and dizziness.
Chronic effects: N.A.
Target organs: Central nervous system, eyes, skin, and respiratory system.
ORL-MOUSE LD50: 1310 mg/kg
IHL-RAT LC50: N.A.
SKN-RBT LD50: N.A.
SECTION 12 — ECOLOGICAL INFORMATION
Data not yet available.
SECTION 13 — DISPOSAL CONSIDERATIONS
Please review all federal, state and local regulations that may apply before proceeding.
Flinn Suggested Disposal Method #18b is one option.
SECTION 14 — TRANSPORT INFORMATION
Shipping name: Camphor. Hazard class: 4.1, Flammable solid. UN number: UN2717.
SECTION 15 — REGULATORY INFORMATION
Not listed.
SECTION 16 — OTHER INFORMATION
This Safety Data Sheet (SDS) is for guidance and is based upon information and tests believed to be reliable. Flinn Scientific, Inc. makes no guarantee of the accuracy or completeness of the data and shall not be liable for any damages relating thereto. The data is offered solely for your consideration, investigation, and verification. The data should not be confused with local, state, federal or insurance mandates, regulations, or requirements and CONSTITUTE NO WARRANTY. Any use of this data and information must be determined by the science instructor to be in accordance with applicable local, state or federal laws and regulations. The conditions or methods of handling, storage, use and disposal of the product(s) described are beyond the control of Flinn Scientific, Inc. and may be beyond our knowledge. FOR THIS AND OTHER REASONS, WE DO NOT ASSUME RESPONSIBILITY AND EXPRESSLY DISCLAIM LIABILITY FOR LOSS, DAMAGE OR EXPENSE ARISING OUT OF OR IN ANY WAY CONNECTED WITH THE HANDLING, STORAGE, USE OR DISPOSAL OF THIS PRODUCT(S).
Consult your copy of the Flinn Science Catalog/Reference Manual for additional information about laboratory chemicals.